Commercial Wall Assemblies

ADDITIONAL EXTERIOR VENEER CLADDING OPTIONS

  • Icynene LD-C-50® and MD-C-200™ pass NFPA 285 Fire Test.
  • Complies with 2006 IBC Chapter 2603.5 for installation in exterior walls of many types I, II, III, IV, and V multi-storey buildings.

In addition to the brick veneer featured in Icynene's Type I and II code compliant exterior wall assembly pictured on the lower-left, ICYNENE LD-C-50® and MD-C-200™ products may also be installed with many other claddings compliant with ASTM E-136 as detailed below:

  • Minimum 4" thick block masonry
  • Stucco over fiber cement board or 5/8" DensGlass®1 sheathing
  • Glass reinforced concrete panels
  • James Hardie®2 board siding panels

Details of the exterior wall covering must be provided to the code official by the report holder, designer, or specifier with an engineering analysis demonstrating that:

  1. The wall covering conforms to ASTM E-136
  2. The addition of the wall covering to the assembly described in Icynene's current ICC-ES Evaluation report for LD-C-50® and MD-C-200™ does not negatively affect conformance of the assembly with the requirements of IBC section 2603.5

 

 

1) Brick Veneer (minimum 4”)

2) Exterior Sheathing 1/2” DensGlass® Gold

3) ICYNENE Spray Foam Insulation

4) Interior Gypsum

5) Steel Stud – up to 6”

 

Click image to enlarge