Icynene - Healthier, Quieter, More Energy Efficient

Making the Icynene name synonymous with superior-quality spray foam insulation, Icynene Classic (LD-C-50) is a one-step quality performance material that both insulates and air seals for the lifetime of the building. Used in thousands of residential and commercial projects since 1986, Icynene Classic (LD-C-50) is guaranteed to perform as specified for the life of the building, consistently outperforming traditional insulation types.

Performance Benefits

  • Stable thermal performance
  • R-value = 3.7 per inch
  • Superior sound control.
  • Vapor permeable, support bi-directional drying of assemblies
  • Soft, flexible composition maintains an air seal even after seasonal expansion/contraction of building assembly
  • <5% water absorption
  • Supports indoor air quality by blocking air infiltration and mass transfer of moisture that may cause mold.
 

Characteristics

  • Open-cell structure with air
  • 100% water-blown
  • Light density 0.5 lb.
  • HFC- and PBDE-free
  • Soft to touch
  • Not a vapor barrier
  • Expands ~100 times from liquid state
  • Application thickness is not limited
  • Low exothermic reaction temperature; will not harm coatings on electrical wiring, plumbing or other building components
  • Lower cost compared to closed-cell products
  • Lowest global warming potential (GWP of 1)
  • A low-emitting material (LEM) as per CHPS EQ 2.2 Section 01350 (Collaborative for High Performance Schools)
 

Construction Benefits

  • Yields of 16,000 to 20,000 board feet
  • Broad range of substrates, temperatures and humidity conditions
  • Superior cold temperature adhesion to multiple substrates
  • Dimensionally stable
  • 1 day occupancy
  • One formulation (no winter/summer)

Thermal and Ignition Barriers

See ESR 1826 for details.

Approved thermal barriers:

  • DC 315 @20 wet mils. (13 dry mils, 80 sq ft/gallon)
  • Alternatively, use a prescriptive thermal barrier

Approved ignition barriers:

  • DC 315 @ 4 wet mils. (3 dry mils, 400 sq ft/gallon)
  • No Burn Plus XD @ 6 wet mils (4 dry mils, 270 sq ft/gallon)
  • Alternatively, use a prescriptive ignition barrier

LEED Contributions

Icynene LD-C-50 meets prerequisites and may contribute towards these LEED for Homes points:

  • EAC1.1: Optimizing Energy Performance
  • EAC1.2: Optimizing Energy Performance
  • EAC2: Insulation
  • EAC3: Air Infiltration
  • MRC2: Environmentally Preferable Products

Applications

Can be used in many residential applications.

And many more applications – find an Icynene licensed contractor to check which Icynene products can be used for your project.

Limitations of Use

Should not be used:

  • Against substrates that may exceed 200°F at installation or in the future
  • Inside electrical outlets or junction boxes
  • Flotation purposes
  • Placed above the roofing membrane
  • Exterior surfaces, exposed and/or in contact with water

Fire Summary

  • ASTM E-84
  • Flame index ≤ 25
  • Smoke index ≤ 450
  • Icynene products are Class 1/Class A Materials