ICYNENE MD-C-200™ is Icynene's leading closed-cell spray foam insulation product from the proven industry leader. It is air-impermeable with a built-in vapor retarder.
MD-C-200 is a one-step performance material which both insulates and air seals a building for the lifetime of the structure.
Icynene MD-C-200 is guaranteed to perform as specified for the life of the building.
Performance Benefits
-
Approved for commercial building types I, II, III, IV, and V construction
-
Stable thermal performance.
-
R-value = 6.0 per inch
-
Class II Vapor Diffusion Retarder @1.5"
-
Rigid, not flexible composition contributes to wall racking strength.
-
Rejects bulk water
-
Supports indoor air quality by blocking air infiltration and mass transfer of moisture that may cause mold.
Characteristics
-
Closed-cell structure
-
Synthetic blown
-
Medium density 2.0 lb. nominal
-
PBDE-free; blown with HFC 245fa
-
Rigid to touch
-
Expands 40 times from liquid state
-
Apply in 2" lifts
-
Will not harm coatings on electrical wiring, plumbing or other building components
-
Lowest global warming potential (GWP of 1020)
-
Approved for construction types: I, II, III, IV, V
-
A low-emitting material (LEM) as per CHPS EQ 2.2 Section 01350 (Collaborative for High Performance Schools)
Construction Benefits
-
Yields of 4,500 board feet
-
Broad range of substrates, temperatures and humidity conditions
-
Superior cold temperature adhesion to multiple substrates
-
Dimensionally stable
-
1 day occupancy
LEED Contributions
Icynene MD-C-200 meets prerequisites and may contribute towards these LEED for Homes points:
-
EAC1.1: Optimizing Energy Performance
-
EAC1.2: Optimizing Energy Performance
-
EAC2: Insulation
-
EAC3: Air Infiltration
-
MRC2: Environmentally Preferable Products
Applications
Can be used in many residential applications:
And many more applications – find an Icynene licensed contractor to check which Icynene products can be used for your project.
Limitations of Use
Should not be used:
-
Against substrates that may exceed 180°F at installation or in the future
-
Inside electrical outlets or junction boxes
-
Flotation purposes
-
Placed above the roofing membrane
-
Exterior surfaces, exposed and/or in contact with water
Thermal and Ignition Barriers
See ESR 3199 for details.
Approved thermal barriers:
-
DC 315 @22 wet mils, 14 dry mils
-
Alternatively, use a prescriptive thermal barrier
Approved ignition barriers:
-
No ignition barrier is required
Fire Summary
-
ASTM E-84
-
Flame index ≤ 25
-
Smoke index ≤ 450
-
Icynene products are Class 1/Class A Materials