Icynene - Healthier, Quieter, More Energy Efficient

ICYNENE MD-R-200represents a revolution in medium density insulating spray foam and air barrier materials. It’s an ideal choice for those who want a more eco-friendly option than closed-cell insulating spray foam, but a higher R-value, compressive strength and tensile strength than what is offered by most open-cell insulating spray foam. Icynene MD-R-200 is guaranteed to perform as specified for the life of the building

Performance Benefits

  • Stable thermal performance.
  • R-value = 5.2 per inch
  • Water blown
  • Low permeance Class 3 VDR (1.8 perm @3" thick)
  • Rigid, not flexible composition contributes to wall racking strength.
  • Rejects bulk water
  • Supports indoor air quality by blocking air infiltration and mass transfer of moisture that may cause mold.

Characteristics

  • Closed-cell structure
  • Synthetic blown
  • Medium density 2.0 lb.
  • HFC- and PBDE-free
  • Rigid to touch
  • Expands 60 times from liquid state
  • Apply in 2" lifts
  • Will not harm coatings on electrical wiring, plumbing or other building components
  • Approved for construction type: V
  • Lowest global warming potential (GWP of 1)
  • A low-emitting material (LEM) as per CHPS EQ 2.2 Section 01350 (Collaborative for High Performance Schools)

Construction Benefits

  • Yields of 6,000 board feet
  • Broad range of substrates, temperatures and humidity conditions
  • Superior cold temperature adhesion to multiple substrates
  • 1 formulation (no summer/winter)
  • Dimensionally stable
  • 1 day occupancy

LEED Contributions

Icynene MD-R-200 meets prerequisites and may contribute towards these LEED for Homes points:

  • EAC1.1: Optimizing Energy Performance
  • EAC1.2: Optimizing Energy Performance
  • EAC2: Insulation
  • EAC3: Air Infiltration
  • MRC2: Environmentally Preferable Products

Applications

Can be used in many residential applications:

And many more applications – find an Icynene licensed contractor to check which Icynene products can be used for your project.

Limitations of Use

Should not be used:

  • Against substrates that may exceed 180°F at installation or in the future
  • Inside electrical outlets or junction boxes
  • Flotation purposes
  • Placed above the roofing membrane
  • Exterior surfaces, exposed and/or in contact with water

Thermal and Ignition Barriers

See ESR 3005 for details.


Approved thermal barriers:

  • Use a prescriptive thermal barrier

Approved ignition barriers:

  • DC315 @4 wet mils (3 dry mils)
  • NoBurn Plus XD @5 wet mils (3 dry mils)

Fire Summary

  • ASTM E-84
  • Flame index ≤ 25
  • Smoke index ≤ 450
  • Icynene products are Class 1/Class A Materials